Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

Please be advised that we are joining the nation in showing our respect to such a wonderful Monarch who dedicated 70 years of loyal and dutiful service to the UK and the Commonwealth. Enrgtech will therefore be closed on Monday 19th September for Her Majesty Queen Elizabeth ll's State Funeral.

0.0 / 5

Reviews 0 Not Rated Yet
Parker UCC Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Parker UCC




New Items
New items
AB.6821301.UC, Parker UCC

AB.6821301.UC, Parker UCC

Metal Cap The AB breather fillers from Parker are lightweight and compact reservoir solutions. The moulded, non-corrodible, glass filled nylon air breathers/fillers combine strength and design. Together with metal filler-breathers, air breathers and lockable filler-breathers, a quality reservoir solution is provided. Features and Benefits •Moulded in non-corrodible, glass filled nylon •Single hole, 6 hole and 3 hole installation •Screw-on breather range – G1/2 and G3/4 •Compact range – G1/4, G3/8, R1/2 and R3/4 •Metal filler breathers •Flange mounting type options •Lockable range for reservoir security and oil protection •Plated mild steel Standards IP65 Supplied with Mounting gaskets and self tapping screws
New items
FM.26 222 129, Parker UCC

FM.26 222 129, Parker UCC

Industrial Flow Indicators - Flowline High-pressure, variable flow indicators with a graduated flow scale on the outer viewing sleeve and an indicator ring which is magnetically coupled to an internal piston. All utilise the technique of differential pressure across a piston which, as the flow increases, moves the piston against a calibrated spring. Can be installed on any plane. Features and Benefits • Pressures up to 350 bar • Flows up to 360 L/min • Accuracy ±5% FSD • Repeatability ±1% FSD • Relatively insensitive to viscosity changes • Direct reading • Oil or water calibrated
New items
FS.643 322 229, Parker UCC

FS.643 322 229, Parker UCC

Industrial Flow Indicator – Boxed version High pressure, variable flow indicator with a graduated flow scale on the outer viewing sleeve and a indicator ring which is magnetically coupled to an internal piston. Utilises the technique of differential pressure across a piston which, as the flow increases, moves the piston against a calibrated spring. Can be installed in any plane without compromising accuracy and is supplied with a manufacturers instruction leaflet. Contains 2 independently adjustable microswitches housed in a metal enclosure with indicating flags showing the switch settings through the viewing window. Supplied with 2 x DIN standard sockets complete with plugs
New items
FM.26 122 329, Parker UCC

FM.26 122 329, Parker UCC

Industrial Flow Indicators - Flowline High-pressure, variable flow indicators with a graduated flow scale on the outer viewing sleeve and an indicator ring which is magnetically coupled to an internal piston. All utilise the technique of differential pressure across a piston which, as the flow increases, moves the piston against a calibrated spring. Can be installed on any plane. Features and Benefits • Pressures up to 350 bar • Flows up to 360 L/min • Accuracy ±5% FSD • Repeatability ±1% FSD • Relatively insensitive to viscosity changes • Direct reading • Oil or water calibrated
New items
FM.26.322 219, Parker UCC

FM.26.322 219, Parker UCC

Oil Calibrated Variable Area Meter Three flow options offer flow measurement in any plane, including the horizontal. Flow through annular orifice, formed by piston bore and a tapered cone, causes a difference in pressure which moves the piston against a calibrated spring. Indicator line viewed against colour-coded scale indelibly printed inside a transparent tube to give direct flow reading. The transparent tube does not cloud or fog up due to all the media being contained inside the metal housing. Features and Benefits •Works in any plane •Pressure up to 350 bar •Flows up to 360 L/min •Accuracy ± 5% FSD •Repeatability ± 1% FSD •Direct Reading •Relatively insensitive to viscosity changes •Oil or water calibrated
New items
FM.26 322 119, Parker UCC

FM.26 322 119, Parker UCC

Oil Calibrated Variable Area Meter Three flow options offer flow measurement in any plane, including the horizontal. Flow through annular orifice, formed by piston bore and a tapered cone, causes a difference in pressure which moves the piston against a calibrated spring. Indicator line viewed against colour-coded scale indelibly printed inside a transparent tube to give direct flow reading. The transparent tube does not cloud or fog up due to all the media being contained inside the metal housing. Features and Benefits •Works in any plane •Pressure up to 350 bar •Flows up to 360 L/min •Accuracy ± 5% FSD •Repeatability ± 1% FSD •Direct Reading •Relatively insensitive to viscosity changes •Oil or water calibrated
New items
AB.687101.UC, Parker UCC

AB.687101.UC, Parker UCC

Screw-on Type Air Breathers The IP65 rated range of moulded, non-corrodible, glass filled nylon air breathers combine strength with a lightweight design. These screw-on type air breathers are non-pressurised and are a proven range of quality reservoir solutions. Features and Benefits •Mouldings in glass filled nylon and glass coupled polypropylene •Available in G3/8, G1/2 and G3/4 •0.2 bar, 0.35 bar and 0.7 bar crack pressure •Nitrile seals
New items
FM.26 222 119, Parker UCC

FM.26 222 119, Parker UCC

Oil Calibrated Variable Area Meter Three flow options offer flow measurement in any plane, including the horizontal. Flow through annular orifice, formed by piston bore and a tapered cone, causes a difference in pressure which moves the piston against a calibrated spring. Indicator line viewed against colour-coded scale indelibly printed inside a transparent tube to give direct flow reading. The transparent tube does not cloud or fog up due to all the media being contained inside the metal housing. Features and Benefits •Works in any plane •Pressure up to 350 bar •Flows up to 360 L/min •Accuracy ± 5% FSD •Repeatability ± 1% FSD •Direct Reading •Relatively insensitive to viscosity changes •Oil or water calibrated
New items
FM.26 322 129, Parker UCC

FM.26 322 129, Parker UCC

Industrial Flow Indicators - Flowline High-pressure, variable flow indicators with a graduated flow scale on the outer viewing sleeve and an indicator ring which is magnetically coupled to an internal piston. All utilise the technique of differential pressure across a piston which, as the flow increases, moves the piston against a calibrated spring. Can be installed on any plane. Features and Benefits • Pressures up to 350 bar • Flows up to 360 L/min • Accuracy ±5% FSD • Repeatability ±1% FSD • Relatively insensitive to viscosity changes • Direct reading • Oil or water calibrated